Technical Data Dynamic Processor
HOME INDEX CLOSE
Technical Data DYNAMIC PROCESSOR
Version 4HE


Input Standard Version
Type electronically balanced
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz ³ + 30 dBu - Gain 3)
Input Impedance ƒ 40 Hz - 15kHz ³ 10 kW
CMRR ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT


Output Standard Version
Type electronically balanced
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu 3)
³ + 22 dBu with unbalanced Load
Source Impedance ƒ 40 Hz - 15 kHz £ 60 W
Load Resistor ³ 1200 W for + 30 dBu ³ 600 W for + 27 dBu
CMRR ƒ 40 Hz - 15 kHz ³ 40 dB according to IEC


Gain 2) all Controls @ 0 dB 1 kHz 0 dB ± 0.5 dB


Frequency Response 2) all Controls @ 0 dB ƒ 20 Hz - 20 kHz ± 0.25 dB
Phase Response 2)
Input/Output ƒ 40 Hz - 15 kHz £ +5°/-20°
Standard RF / Subsonic Filters


THD 3) £ +22 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 %


Dynamic Range 2) Vu 0 dB/22Hz-22kHz RMS ³ 116 dB - Gain
Noise Level 2) Vu 0 dB / 22Hz-22kHz RMS £-90 dBu


Size INTEGRATOR-Standard Cassette 4HE


Control Elements Potentiometer
Limiter
activated by Threshold Control
Limiter is activ if Compressor and/or Gate is on
Threshold - 4 dBr to OFF (above + 30 dBu)
Attack 50 µs fixed
Release basically 0.3 s, Programm controlled
Meter
3 Colour Led - Range 10 dB
Green: off, Yellow: on Threshold
Orange to Red: 1 to 10 dB'
Compressor activted by COMP Swtich
Threshold - 30 to + 20 dBr
Attack 100 µs to 30 ms
Release 50 ms bis 5 s
Knee
Soft Junction Range by 3 Position Switch
OFF, 3 dB, 6 dB
Gain calibrated 0 dB, Center Detent, Range ± 20 dB
Ratio 1:1 via oo (Limit)
Crest
RMS Converter Integration Time, by Switch,
3 Steps, Peak, MD (Medium), RMS (Slow)
Env(elope)
Converter Low Frequency Treatment
by Switch, Off and 2 Steps
Display
5 Led's, Range 1 to 20 dB
Autogain
affected by THR, RAT and ATT
not affected by CREST and KNEE
separate ON/OFF Switch for Autogain
Gate separate ON/OFF switch
Threshold -40 dBr to 12 dBr
Attack
0.01 ms to 5 ms
Release 0.05 s to 5 s
Hold
0.05 s to 5 s
Range
Gate closed Attenuation 0 to 80 dB
Low Pass Filter > 20 kHz to 200 Hz, 12 dB/Oct
High Pass Filter > 20 Hz to 3 kHz, 12 dB/Oct.
Display
3 Led's, Green: Open, Yellow: Hold, Red, Closed
Side Chain Listen
SCL Switch routs Rectifier Input to Output


1) Depending on the settings of the controls gain and attenuation is possible. Value refers to the higher level on input or output.
2)
all Dynamics inactive
3) Conditional on physical principles, the setting of compressor and expander can affect the harmonic distortion performance. Data refers to inactive compressor and expander.