| Technical Specifications |
STEREO-CONTROL ROOM UNIT W760 |
| Size |
V700-Module 1N |
|
| Input |
stereo |
| Type |
balanced floating/Transformer
or balanced, grounded |
| nominal Level |
+ 6 dBu |
| maximum Level1) |
ƒ ³ 40 Hz ³ + 30 dBu |
| Input Impedance |
ƒ 40 Hz - 15kHz ³ 25 kW |
| CMRR |
ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT |
|
| Output |
stereo |
| Type |
balanced floating/Transformer
or balanced, grounded |
| nominal Level |
+ 6 dBu |
| maximum Level1) |
ƒ ³ 40 Hz, kges 1 % ³ + 26 dBu |
| Source Impedance |
ƒ 40 Hz - 15 kHz £ 60 W |
| Load Resistance |
³ 600 W |
| CMRR |
ƒ £ 15 kHz ³ 40 dB according to IEC |
| CMRR |
ƒ £ 15 kHz ³ 60 dB according to IRT |
|
| Gain 2) |
all Controls at 0 dB Position 1 kHz 0 dB ± 0.5 dB |
|
| Frequency Response |
ƒ 20 Hz - 20 kHz ± 0.5 dB |
| Phase Response |
- Input/Output ƒ 40 Hz - 15 kHz £ +5°/-20°
- with Standard Values for RF & LF Filters
|
|
| THD |
£ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 % |
|
| Dynamic Range |
22Hz-22kHz RMS ³ 120 dB |
| Noise Level |
22Hz-22kHz RMS £-90 dBu |
|
| Crosstalk |
Links <> Rechts ƒ 40 Hz - 15 kHz £ -70 dB |
|
| Size |
V700 Standard Module Size, standard Depth |
| Frame |
- fits into Standard Frames
- Adaptor necessary
|
|
| Control Elements |
Stepper Switch / Stepper Pots
|
- Volume Control
|
- 21 Steps from Off to 92 dB-SPL
- Gain at 92 dB-SPL 0 dB ± 0.25 dB
- without Matrix Stages and Direction Control active
|
| Direction Control |
- 21 Steps from 'left only' to 'right only'
- calibrated in % of half the stereo base width
- 0 Position ± 0.25 dB
|
|
| Headphone |
- Kopfhörerausgang with Offsetregler zur Anpassung der Lautstärke, for Kopfhörer 4W to 2kW
|
| PFL |
- activated by Push Button or by Remote Control Voltage, isolated by Opto Coupler 9 to 30 V
- additional, balanced Input
- Level Control
|
| DIM |
- Control Range from 10 to 30 dB
- activated by Push Button or by Remote Control Voltage, isolated by Opto Coupler
|
|
| Monomatrix |
internal Selection of 3 dB or 6 dB Operation activated by Push Button MONO |
| Left-Right Reversal |
by Push Button L<>R
|
| Phase Reversal |
in right Channel by Push Button ØR |
| Muting |
all Outputs by Push Button CUT |
| 2. Abhöranlage |
passiv selection by Push Button ALT |
|
|
| 1) |
Depending on the setting of the control, gain or attenuation is possible. The value is valid for the higher level at the input or output. |
|
| 2) |
Refers to linear adjustment of all parameters |
|
| Index |
Home V700 Home |