CLOSE
Technical Specifications COMPRESSOR LIMITER NOISE GATE U799
Size V700-Module 1N

Input
Type balanced, floating, torodial Transformer, or balanced, grounded
nominal Level + 6 dBu
maximum Level 1) ƒ ³ 40 Hz ³ + 30 dBu
Input Impedance ƒ 40 Hz - 15kHz ³ 5 kW
CMRR ƒ 40 Hz - 15 kHz ³ 60 dB according to IRT
S-C-Input stereo
Type balanced, grounded
nominal Level + 6 dBu
maximum Level 1) ƒ ³ 40 Hz ³ + 30 dBu
Input Impedance ƒ 40 Hz - 15kHz ³ 5 kW
CMRR ƒ 40 Hz - 15 kHz ³ 60 dB according to IRT

Output stereo
Type balanced, floating, torodial Transformer, or balanced, grounded
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu
Source Impedance ƒ 40 Hz - 15 kHz £ 40 W
Load Resistance ³ 300 W
CMRR ƒ £ 15 kHz ³ 40 dB according to IEC
CMRR ƒ £ 15 kHz ³ 60 dB according to IRT
S-C Output
Type balanced, grounded
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu
Source Impedance ƒ 40 Hz - 15 kHz £ 60 W
Load Resistance ³ 1200 W
CMRR ƒ £ 15 kHz ³ 40 dB according to IEC

Gain 2) all Controls at 0 dB Position 1 kHz 0 dB ± 0.5 dB

Frequency Response 2) ƒ 20 Hz - 20 kHz ± 0.25 dB
Phase Response 2)
Input/Output ƒ 40 Hz - 15 kHz £ +5/-20°
with Standard Values for RF & LF Filters

THD 3) £ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 %

Dynamic Range 2) Gain 0 dB / 22Hz-22kHz RMS ³ 120 dB
Noise Level 2) Gain 0 dB / 22Hz-22kHz RMS £-90 dBu

Size V700-Module - StandardSize
Frame fits into Standard Frames

Control Elements Stepper Pots - 21 Steps
Compressor activated by Push Button DYN
Threshold -30 dBu ... + 18 dBu
Attack 0.1 ms ... 30 ms
Release 50 ms ... 5 s
Ratio 1:1 to oo
Knee Threshold Transfer Range 0 to > 12 dB
Crest 4 Steps from 0.3 to 8
Envelope Controlled
Fill Parallel Compression by adding the Input Signal
range from Off to -6 dB
Autogain ± 1.5 dB at Crest =1 and Env = 0, switched
Gain 0 dB ± 0.3 dB - Control Range ± 20 dB
S-C-Insert
Side-Chain Inser for external EQ's etc.
selected Push Button SC-INS
Output is always active
Input is switched
Level at S-C-Ins + 6 dBu
Display
Gain-Reduction with 8 Led's, 1 to 20 dB

Noise Gate
activated byPush Button GATE
Threshold
- 30 dBu ... +21 dB
Attack 0.02 ms ... 10 ms
Release 50 ms ... 3 s
Hold 50 ms ... 3 s
Range
from 0 to 80 dB
double logarithmic Law
Bandpass Filter by Push Button BPF
Frequency Range 50 Hz to 8 kHz
Q-Factor Range 3 Okaves to a Third
High Pass/Low Pass Filter activated by Push Button FILT
Frequency Range High-pass 50 Hz to 8 kHz
Frequency Range Low-pass 15 kHz to 50 Hz
Steepness 12 dB/Oct.
Side Chain Listen Push Button SCL switches the internal Side Chain input of the Gate to the Output

Limiter activated by
Push-Pull Switch of the Threshold Pot
Threshold -6 dB ... >+ 24 dB (0 dB = + 6 dBu)
Attack 0.01 ms ... 5 ms
Release 0.05 sec ... 5 sec
Ratio Increase of 20 dB at the input results max ± 0.3 dB change in Output Level
Display 3 Color-LED
Grün, no Regulation
Gelb, Treshold Level
Orange/Rot, display Gain Reduction
from Orange to Red at 6 dB Gain Reduction

Bypass durch Push Button DYN-ON
Signal Flow
Compressor, Limiter and Gate use separate VCA's and Control Voltage Generatrion
Thr Limiter is always installed directly pre output driver. Compressor and Gate can be reversed by the push-pull switch of the compressor threshold pot. The default configuration is:
Compressor - Gate Limiter

1)
Depending on the setting of the control, gain or attenuation is possible. The value is valid for the higher level at the input or output.

2)
No Dynamic Regulation active
(Ratio-Regler all to the left)

3)
The settings and the signal frequency can affect the THD values. The values refer to inactive regulation.

Index Home V700 Home