Technical Specifications |
NIVEAU-FILTER with HI-EQ + LOW-EQ W795 |
Size |
V700-Module 1N |
|
Input |
stereo |
Type |
balanced, floating, torodial Transformer, or balanced, grounded |
nominal Level |
+ 6 dBu |
maximum Level1) |
ƒ ³ 40 Hz ³ + 30 dBu |
Input Impedance |
ƒ 40 Hz - 15kHz ³ 5 kW |
CMRR |
ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT |
|
Output |
stereo |
Type |
balanced, floating, torodial Transformer, or balanced, grounded |
nominal Level |
+ 6 dBu |
maximum Level1) |
ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu |
Source Impedance |
ƒ 40 Hz - 15 kHz £ 40 W |
Load Resistance |
³ 300 W |
CMRR |
ƒ £ 15 kHz ³ 40 dB according to IEC |
CMRR |
ƒ £ 15 kHz ³ 60 dB according to IRT |
|
Gain 2) |
all Controls at 0 dB Position 1 kHz 0 dB ± 0.5 dB |
|
Frequency Response 2) |
ƒ 20 Hz - 20 kHz ± 0.5 dB |
Phase Response 2) |
- Input/Output ƒ 40 Hz - 15 kHz £ +5°/-20°
- with Standard Values for RF & LF Filters
|
|
THD |
£ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 % |
|
Dynamic Range 2) |
22Hz-22kHz RMS ³ 120 dB |
Noise Level 2) |
22Hz-22kHz RMS £-90 dBu |
|
Crosstalk |
L <> R ƒ 40 Hz - 15 kHz £ - 70 dB |
|
Size |
V700 Standard Module Size, standard Depth |
Frame |
fits into Standard Frames |
|
Control Elements |
- Stepper Pot
|
HI-Boost/Cut Range |
max. ± 16 dB ± 1 dB with Center Detent at 0 dB |
Frequency HI |
14 kHz to 35 kHz |
Charakteristics HI |
Baxandall-Filter 9 dB/Oct. |
|
Niveau Boost/Cut |
max. ± 16 dB ± 1 dB with Center Detent at 0 dB |
Characteristics |
- synchronous Boost and Cut
- of High and Low with Baxandall Characteristics
- neutral Frequency 800 Hz
|
Niveau Balance |
max. ± 16 dB ± 1 dB with Center Detent at 0 dB |
Characteristics |
- counterrotating Boost and Cut
- of High and Low with Baxandall Characteristics
- neutral Frequency 800 Hz
|
|
Control Elements |
- Stepper Pot
|
Low Boost/Cut Range |
max. ± 16 dB ± 1 dB with Center Detent at 0 dB |
Frequency LOW |
10 Hz to 320 Hz |
Charakteristics |
Baxandall-Filter 9 dB/Oct. |
|
|
Bypass |
- Hard Bypass-Switch
|
|
1) |
Depending on the setting of the control, gain or attenuation is possible. The value is valid for the higher level at the input or output. |
|
2) |
The values refer to precisely linear setting of all parameters. |
|
Index |
Home V700 Home |