Technical Specifications |
90 DEGREE FILTER V724 |
Size |
V700-Module 1N |
|
Input |
stereo |
Type |
balanced, floating, torodial Transformer, or balanced, grounded |
nominal Level |
+ 6 dBu |
maximum Level1) |
ƒ ³ 40 Hz ³ + 30 dBu |
Input Impedance |
ƒ 40 Hz - 15kHz ³ 5 kW |
CMRR |
ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT |
|
Output |
stereo |
Type |
balanced, floating, torodial Transformer, or balanced, grounded |
nominal Level |
+ 6 dBu |
maximum Level1) |
ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu |
Source Impedance |
ƒ 40 Hz - 15 kHz £ 40 W |
Load Resistance |
³ 300 W |
CMRR |
ƒ £ 15 kHz ³ 40 dB according to IEC |
CMRR |
ƒ £ 15 kHz ³ 60 dB according to IRT |
|
Gain |
- depends on selected Function
|
|
Frequency Response |
ƒ 20 Hz - 20 kHz ± 0.25 dB |
Phase Response |
controlled |
|
THD |
£ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 % |
|
Dynamic Range |
22Hz-22kHz RMS ³ 122 dB |
Noise Level |
22Hz-22kHz RMS £-92 dBu |
|
Size |
V700 Standard Module Size, standard Depth |
Frame |
fits into Standard Frames |
|
Function |
- Matrix with 90-degree-Filter
- for Mode Stereo to Mono
- and Mono to Pseudo Stereo
- selected by Switch
|
- Control Elements
|
- Phase difference between the left and right Input Channels in Stereo to Mono Mode and between left and right Output Channel in Mono to Pseudo Stereo Mode
-
|
Control Range |
Phase Difference 45 Grad to 135 Grad |
|
1) |
Depending on the settings, gain or attenuation can occur. The Value refers to the higher level. |
|
Index |
Home V700 Home |