CLOSE
Technical Specifications LIMITER U777
Size Mono in V700-Module 1N

Input
Type balanced, floating, torodial Transformer, or balanced, grounded
nominal Level + 6 dBu
maximum Level 1) ƒ ³ 40 Hz ³ + 30 dBu
Input Impedance ƒ 40 Hz - 15kHz ³ 5 kW
CMRR ƒ 40 Hz - 15 kHz ³ 60 dB according to IRT

Output
Type balanced, floating, torodial Transformer, or balanced, grounded
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu
Source Impedance ƒ 40 Hz - 15 kHz £ 40 W
Load Resistance ³ 300 W
CMRR ƒ £ 15 kHz ³ 40 dB according to IEC
CMRR ƒ £ 15 kHz ³ 60 dB according to IRT

Gain 2) all Controls at 0 dB Position 1 kHz 0 dB ± 0.5 dB

Frequency Response 2) ƒ 20 Hz - 20 kHz ± 0.25 dB
Phase Response 2)
Input/Output ƒ 40 Hz-15 kHz £ +5/-20°
with Standard Values for RF & LF Filters

THD 3) £ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 %

Dynamic Range 2) 22Hz-22kHz RMS ³ 122 dB
Noise Level 2) 22Hz-22kHz RMS £-92 dBu

Size V700-Module - StandardSize
Frame fits into Standard Frames

Control Elements Stepper Pots - 21 Steps
Threshold -4 dBr ... + 16 dBr - 0 dBr = + 6 dBu
Attack 0.02 ms ... 10 ms
Release 100 ms ... 3 s
Ratio > 50 : 1
Input Gain Input Gain Control pre Limiter
0 dB ± 0.2 dB, Range +/- 10 dB
Output Gain Output Gain Control post Limiter
0 dB ± 0.2 dB, Range +/- 10 dB
Display
Gain-Reduction with 9 Led's, 1 to 20 dB

1)
abhängig von den Reglerstellungen sind Dämpfungen innerhalb des Gerätes möglich. Der Wert gilt jeweils for den höheren Level am Input or Output

2)
at Inaktivem Liwither - Level below Threshold

3)
Die Einstellung des Begrenzers kann sich physikalisch bedingt to die Klirrfatoren auswirken. Die Werte gelten at inaktivem Liwither (with Level unter Threshold)

Index Home V700 Home