Technical Data RMS Compressor - I77
HOME INDEX CLOSE
Technical Data RMS COMPRESSOR I77
Version 3HE


Input Standard Version
Type electronically balanced
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz ³ + 30 dBu - Gain 3)
Input Impedance ƒ 40 Hz - 15kHz ³ 10 kW
CMRR ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT
Input optional Version -s
Type balanced floating, Transformer
nominal Level + 6 dBu ± Gain
maximum Level1) ƒ ³ 40 Hz ³ + 30 dBu - Gain 3)
Input Impedance ƒ 40 Hz - 15kHz ³ 10 kW
CMRR ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT


Output Standard Version
Type electronically balanced
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu 3)
³ + 22 dBu with unbalanced Load
Source Impedance ƒ 40 Hz - 15 kHz £ 60 W
Load Resistor ³ 1200 W for + 30 dBu ³ 600 W for + 27 dBu
CMRR ƒ 40 Hz - 15 kHz ³ 40 dB according to IEC
Output optional Version -s
Type balanced floating, Transformer
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu 3)
Source Impedance ƒ 40 Hz - 15 kHz £ 60 W
Load Resistor ³ 1200 W for + 30 dBu ³ 600 W for + 27 dBu
CMRR ƒ £ 15 kHz ³ 40 dB according to IEC
CMRR ƒ £ 15 kHz ³ 60 dB according to IRT


Gain 2) all Controls @ 0 dB 1 kHz 0 dB ± 0.5 dB


Frequency Response 2) all Controls @ 0 dB ƒ 20 Hz - 20 kHz ± 0.25 dB
Phase Response 2)
Input/Output ƒ 40 Hz - 15 kHz £ +5°/-20°
Standard RF / Subsonic Filters


THD 3) £ +22 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 %


Dynamic Range 2) Vu 0 dB/22Hz-22kHz RMS ³ 116 dB - Gain
Noise Level 2) Vu 0 dB / 22Hz-22kHz RMS £-90 dBu


Size INTEGRATOR-Standard Cassette 4HE / 3HE


Control Elements Potentiometer
Compressor THR - 30 to + 20 dBr
Compressor ATT 100 µs to 30 ms
Compressor REL 100 ms to 5 s
Compressor RAT 1 : 1 to oo
Autogain on / off Switch, ± 1 dB
Expander THR - 50 to 0 dBr
Expander ATT fast
Expander REL automatic
Expander RAT exponential
Expander activated by Swtich EXP-ON
Meter 8 Led's'


1) Depending on the settings of the controls gain and attenuation is possible. Value refers to the higher level on input or output.
2)
Compressor and Expander inactive
(Ratio Controls at Position 1:1/Expander OFF)
3) Conditional on physical principles, the setting of compressor and expander can affect the harmonic distortion performance. Data refers to inactive compressor and expander.