Technical Data expandable Mixer C41 Cascade
HOME INDEX CLOSE
Technical Data EXPANDABLE MIXER C41 CASCADE
Version 4HE


Inputs 4 x Stereo Main Input + 1 Stereo Extention Input
Type electronically balanced
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz ³ + 30 dBu - Gain
Input Impedance ƒ 40 Hz - 15kHz ³ 10 kW
CMRR ƒ 40 Hz £ 15 kHz ³ 60 dB according to IRT


Outputs Stereo Main Output and Stereo Couple Output
Main Output
Type electronically balanced
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ +30 dBu
³ + 24 dBu unbalanced Connection
Source Impedance ƒ 40 Hz - 15 kHz £ 60 W
Load Resistor ³ 1200 W for + 30 dBu ³ 600 W for + 27 dBu
CMRR ƒ 40 Hz - 15 kHz ³ 40 dB according to IEC
Couple Output
Type electronically balanced
nominal Level + 6 dBu
maximum Level1) ƒ ³ 40 Hz, kges 1 % ³ + 30 dBu
Source Impedance ƒ 40 Hz - 15 kHz £ 60 W
Load Resistor ³ 2 kW
CMRR internal use only, undefined
unbalanced Connection not allowed


Gain Gain Switch and Level Control
Gain Switch and 3 position Switch, -10 / 0 / + 10 dB ± 0.5 dB
Level Control + 10 dB max, 0 dB Position calibrated
Couple Input fixed Gain 0 dB ± 0.2 dB


Frequency Response ƒ 20 Hz - 20 kHz ± 0.25 dB
Phase Response
Input/Output ƒ 40 Hz - 15 kHz £ +5°/-20°
normal RF Filters
Input/Couple Output
ƒ 40 Hz - 15 kHz £ ±3°
(Couple Input + Couple Output unfiltered)


THD £ +22 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 %


Crosstalk between L + R ƒ 40 Hz - 15 kHz £ 60 dB between Inputs ƒ 40 Hz - 15 kHz £ 80 dB


Dynamic Range Vu 0 dB/22Hz-22kHz RMS ³ 120 dB - Gain
Dynamic Range
Noise Level Vu 0 dB / 22Hz-22kHz RMS £-94 dBu
Noise Level


Size INTEGRATOR-Standard Cassette 4HE
Frame extended Frame Version 4HE/E required


Control Elements Potentiometer
Level Off ... + 10 dB / 0 dB calibrated
Pan/Bal - 3 dB @ Center, Center Detent
Gain Gain values refer to Pan @ Center Position
Gain Control 3 position Switch
Cut / Solo 3 position Switch
Level Display 2 3-Color-LED's per Main Input / Peak-Present
Cut Off Attenuation Level Control ƒ 40 Hz - 15 kHz £ 80 dB
Cut Off Attenuation Cut-/Solo ƒ 40 Hz - 15 kHz £ 90 dB
Solo Control can be coupled to other moduls
Extention Input Enable Input (Bridge on 9 SubD)


1) Depending on the setting of the controls gain or attenuation is possible. Value refers to the higher level on input or output.