Technical Specifications |
BAL-CONTROL STEREO to 5·1-SRD W749 |
Size |
V700-Module 05G |
|
Input |
Stereo |
Type |
balanced, grounded |
nominal Level |
+ 6 dBu |
maximum Level |
³ + 30 dBu |
Input Impedance |
ƒ 40 Hz - 15kHz ³ 5 kW |
CMRR |
ƒ 40 Hz - 15 kHz ³ 60 dB according to IRT |
|
Output 1 |
6 Channel-Surround-Main Output |
Type |
balanced, grounded |
nominal Level |
+ 6 dBu |
maximum Level |
kges 1 % ³ + 30 dBu |
Source Impedance |
ƒ 40 Hz - 15 kHz £ 40 W |
Load Resistance |
³ 300 W |
CMRR |
ƒ £ 15 kHz ³ 40 dB according to IEC |
Output 2 |
6 Channel, for V700 Bus Rails |
|
Gain |
- @ L/R/C*/LS/RS/LFE* 0 dB ± 0.25 dB
- in corresponding Positions with DIV = -100 %
- * Kanäle C and LFE = Matrix-Output
|
Mono-Matrix |
- Channels C and LFE driven from Matrix, adding L and R
- Matrix Attenuation 6 dB
- internally adjustable 0 to 8 dB
|
|
Frequency Response |
ƒ 20 Hz - 20 kHz ± 0.25 dB |
Phase Response |
ƒ 40 Hz - 15 kHz £ +5°/-20° |
|
THD |
£ +26 dBu, ƒ ³ 40 Hz - 15 kHz, kges £ 0.1 % |
|
Infinity Cut Off |
ƒ 40 Hz - 15 kHz £ 70 dB |
|
Dynamic Range |
22Hz-22kHz RMS ³ 130 dB |
Noise Level |
22Hz-22kHz RMS £-100 dBu |
|
Size |
V700-Module - 2.5 U high - Fader Depth |
Frame |
for Console Frames and Custom Frames only |
|
Control Elements |
Stepper Pots - 21 Steps |
Type |
Direction Control between 6 Channels |
LCR-Pan |
- with Divergence @ -100 %
- and Front-Surround-Pan @ Front
- 0 dB ± 0.25 dB @ L, C * and R
- Attenuation at 50 % L-C and 50 % C-R - 3 dB
- with Front-Surround-Pan @ SRD
- LS and RS in Position L or R 0 dB ± 0.25 dB
- Center Attenuation LS / RS 3 dB 0.25 dB
- * Matrix-Ausgangssignal
|
Divergence |
- Level to L and R @ C of the LCR-Pan
- and Level to C (siehe Text)
|
Front-Surround-Pan |
- Control Elements (L + C + R) gegen (LS + RS)
- Attenuation 0 dB ± 0.25 dB
- Center Position 3 dB ± 0.25 dB
|
LFE |
- Independent Control
- 0 to 100 % of the Matrix-Output Signal
- to Channel LFE
|
|
Index |
Home V700 Home |