CLOSE
Technical Specifications 2 VU-METER U775
Size in V700-Module 2N

Input
Type balanced floating/Transformer
or balanced, grounded
nominal Level + 6 dBu
maximum Level ƒ ³ 40 Hz ³ + 30 dBu
Input Impedance ƒ 40 Hz - 15kHz ³ 20 kW
CMRR ƒ 40 Hz - 15 kHz ³ 60 dB according to IRT

Gain
0 dB Display adjustable from
- 6 dBu to + 22 dBu
Standard Setting + 6 dBu for 0 dB VU
with 4 dB Lead

Frequency Response ƒ 20 Hz - 20 kHz ± 0.2 dB
RF-Filter 6 dB/Octave

Noise no Display

Crosstalk L-R, ƒ 40 Hz - 15 kHz no Display, any Level

Measuring Mode Average with 300 ms Attack- and Release
Display VU-Meter
Accuracy
+ 3 dB to - 10 dB ± 0.5 dB
below - 10 dB < 1.5 dB
Overshoot < 1 dB with 1 kHz Burst

Size V700-Module - double Wide - Standard Depth
Frame for Standard Frames - needs 2 Slots

Index Home V700 Home